Customization: | Available |
---|---|
Application: | Three Phase Transducer, High Frequency Converter Transducer |
Output Type: | Single |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
The frequency converter can be automatically adjusted according to the load characteristics.. Wide range of functions, applicable to most applications
Open loop/closed loop vector control,V/F control (built-in PID) of synchronous and asynchronous motors
Item | T9000 | |
Basic function | Control Mode | V/F contro Sensorless flux vector control (SVC) Close-loop vector control (FVC)(Above 3.7KW) |
Maximum frequency | 600Hz | |
Carrier frequency | 0.5kHz~8kHz The carrier frequency is automatically adjusted based on the load features. |
|
Input frequency resolution | Digital setting:0.01Hz Analog setting:Maximum frequency x 0.025% |
|
Start torque | G Type:0.5Hz/150%(SVC) P Type:0.5Hz/100% |
|
Speed range | 1:100 (SVC) | |
Basic function | Speed stability accuracy | ±0.5%(SVC) |
Overload capacity | G Type:60s for 150%of the rated current 3s for 180%of the rated current P Type:60s for 120%of the rated current, 3s for 150%of the rated current |
|
Torque boost | Auto-boost Customized boost:0.1%~30.0% |
|
V/F Curve | Straight-line V/F curve Multi-point V/F curve N-power V/F curve(1.2-power,1.4-power,1.6-power,1.8-power,square) |
|
V/F separation | 2 types:complete separation;half separation | |
Ramp Mode | Straight-line ramp Four groups of acceleration/deceleration time with the range of 0.00'6500.0s |
|
DC braking |
DC braking frequency:0.00Hz~Maximum frequency Braking time:0.0s~36.0s Braking action current value:0.0%~100.0% |
|
JOG control | JOG frequency range:0.00Hz~50.00Hz JOG acceleration/deceleration time:0.0s~6500.0s |
|
Simple PLC,Multiple preset speeds | It implements up to 16 speeds via the simple PLC function or combination of terminal states | |
Onboard PID | It realizes process-controlled closed loop control system easily | |
Auto voltage regulation(AVR) |
It can keep constant output voltage automatically when the mains voltage changes | |
Overvoltage/overcurrent stall control |
The current and voltage are limited automatically during the running process so as to avoid frequent tripping due to over voltage/over current |
|
Rapid current limit | It helps to avoid frequent over current faults of the AC drive | |
Torque limit and control | It can limit the torque automatically and prevent frequent over current tripping during the running process.Torque control can be implemented in the FVC mode |
|
Individualized functions | High performance | Control of asynchronous motor are implemented through the high-performance current vector control technology |
Rapid dip ride through | The load feedback energy compensates the voltage reduction so that the AC drive can continue to run for a short time |
|
Support for multiple PG card |
Support for differential input PG card,resolver PG card,rotating transformer PG card… | |
Rapid current limit | t helps to avoid frequent over current faults of the AC drive | |
Timing control | Timing range:0.0Min~6500.0Min | |
Communication methods | RS-485 | |
Running | Command source | Operation panel/Control terminals/Serial communication port You can perform switchover between these sources in various ways |
Frequency source | There are ten frequency sources Digital setting,analog voltage setting,analog current setting,pulse setting,serial port setting You can perform switchover in various ways |
|
Auxiliary frequency source | There are ten auxiliary frequency sources.It can implement fine tuning of auxiliary frequency and frequency synthesis |
|
Input terminal | Standard:4 digital input terminals(Below 5.5KW)/6 digital input terminals(Above 7.5KW) 1 analog input terminal(Below 5.5KW)/2 analog input terminals(Above 7.5KW); 1 voltage input (only support for 0~10V,above 7.5KW),1 voltage input(0~10V)or current input (4~20mA) |
|
Output termina | 1 High-speed pulse output terminal (Open-collector)(Above 3.7KW) 1 replay output terminal (Below 5.5KW)/2 replay output terminals(Above 7.5KW) 1 analog output terminal(3.7KW~5.5KW)/2 analog output terminal(Above 7.5KW) Support for 4~20mA current output or 0~10V voltage output |
|
Display and operation panel | LED display | It displays the parameters |
Key locking and function selection |
It can lock the keys partially or completely and define the function range of some keys so as to prevent mal-function |
|
Protection mode | Motor short-circuit detection at power-on,input/output phase loss protection,over current protection,over voltage protection,under voltage protection,overheat protection and overload protection |
|
Environment |
Installation location | Indoor,free from direct sunlight,dust,corrosive gas,combustible gas,oil smoke,vapor drip or salt |
Altitude | Lower than 1000m | |
Ambient temperature | -10°C~+40°C(de-rated if the ambient temperature is between 40°C~50°C | |
Humidity | Less than 95%RH,without condensing | |
Vibration | Less than 5.9m/s2(0.6g) | |
Storage temperature | -20°C~+60°C |
Model | Rated output | Rated input | Rated output | Motor Power(KW) |
power(kW) | current(A) | current(A) | ||
Input voltage:1PH AC220V±15% | ||||
T9200-0R4G | 4 | 5.4 | 2.1 | 0.4 |
T9200-0R75G | 0.75 | 7.2 | 3.8 | 0.75 |
T9200-1R5G | 1.5 | 10 | 7.2 | 1.5 |
T9200-2R2G | 2.2 | 16 | 9 | 2.2 |
T9200-3R7G | 3.7 | 17 | 17 | 3.7 |
Input voltage; 3PH AC380V±15% | ||||
T9400-0R4G | 0.4 | 3.4 | 1.5 | 0.4 |
9400-0R75G | 0.75 | 3.8 | 2.1 | 0.75 |
T9400-1H5G | 1.5 | 5 | 3.8 | 1.5 |
T9400-2R2G | 2.2 | 5.8 | 5.1 | 2.2 |
T9400-3R7G/5R5P | 3.7/5.5 | 10/15 | 9/13 | 3.7/5.5 |
T9400-5R5G/7R5P | 5.5/7.5 | 15/20 | 13/17 | 5.5/7.5 |
T9400-7R5G/11P | 7.5/11 | 20/26 | 17/25 | 7.5/11 |
T9400-11G/15P | 11/15 | 26/35 | 25/32 | 11/15 |
T9400-15G/18.5P | 15/18.5 | 35/38 | 32/37 | 15/18.5 |
T9400-18.5G/22P | 18.5/22 | 38/46 | 37/45 | 18.5/22 |
T9400-22G/30P | 22/30 | 46/62 | 45/60 | 22/30 |
9400-30G/37P | 30/37 | 62/76 | 60/75 | 30/37 |
9400-37G/45P | 37/45 | 76/90 | 75/91 | 37/45 |
T9400-45G/55P | 45/55 | 90/105 | 91/112 | 45/55 |
T9400-55G/75P | 55 | 105 | 112 | 55 |
T9400-75P | 75 | 140 | 150 | 75 |
T9400-75G/90P | 75/90 | 140/160 | 150/176 | 75/90 |
T9400-90G/110P | 90/110 | 160/210 | 176/210 | 90/110 |
T9400-110G/132P | 110/132 | 210240 | 210/253 | 110/132 |
T9400-132G/160P | 132/160 | 240/290 | 253/304 | 132/160 |
T9400-160G/185P | 160/185 | 290/330 | 304/340 | 160/185 |
T9400-185G/200P | 185/200 | 330/370 | 340/377 | 185/200 |
T9400-200G/220P | 200/220 | 370/410 | 377/426 | 200/220 |
T9400-220G/250P | 220/250 | 410/460 | 426/465 | 220/250 |
T9400-250G/280P | 250/280 | 460/50 | 465/520 | 250/280 |
T9400-280G/315P | 280/315 | 500/58 | 520/585 | 280/315 |
T9400-315G/350P | 315/350 | 580/620 | 585/650 | 315/350 |
T9400-350G/400P | 350/400 | 620/670 | 650/725 | 350/400 |
T9400-400G/450P | 400/450 | 670/790 | 725/820 | 4001450 |
T9400-450G/500P | 450/500 | 790/835 | 820/880 | 450/50 |
SIZE | Model | W | H | D | A | B | φd |
A | T9200-0R4G | 72 | 142 | 127 | 130 | 61 | 4.5 |
T9200-0R75G | |||||||
T9200-1R5G | |||||||
T9200-2R2G-VF | |||||||
T9400-0R4G | |||||||
T9400-0R75G | |||||||
T9400-1R5G | |||||||
T9400-2R2G | |||||||
T9200-2R2G | 85 | 180 | 131 | 167 | 72 | 5.5 | |
T9200-3R7G | |||||||
T9400-3R7G/5R5P | |||||||
T9400-5R5G/7R5P | |||||||
B | T9400-7R5G/11P | 106 | 240 | 168 | 230 | 96 | 4.5 |
T9400-11G/15P | |||||||
T9400-15G/18.5P | 151 | 332 | 183 | 318 | 137 | 7 | |
T9400-18.5G/22P | |||||||
T9400-22G/30P | |||||||
T9400-30G/37P | 217 | 400 | 216 | 385 | 202 | 7 | |
T9400-37G/45P |
SIZE | Model | W | H | H1 | D | A | B | ∅d |
C | T9400-45G/55P | 300 | 440 | 470 | 240 | 200 | 455 | 9 |
T9400-55G | ||||||||
T9400-75P | ||||||||
T9400-75G/90P | 275 | 590 | 630 | 310 | 200 | 612 | 9 | |
T9400-90G/110P | ||||||||
T9400-110G/132P | ||||||||
T9400-132G/160P | 400 | 675 | 715 | 310 | 320 | 695 | 11 | |
T9400-160G/185P |
SIZE | Model | Outline dimention (mm) |
Installation Size(mm) |
Wall- mounted Size(mm) |
|||||||||
W | H | H1 | H2 | D | a1 | b1 | d1 | a2 | a3 | b2 | d2 | ||
D | T9400-185G/200P | 300 | 1445 | 1180 | 200 | 500 | 250 | 430 | 14 | 220 | 150 | 1135 | 13 |
T9400-200G/220P | |||||||||||||
T9400-220G/250P | |||||||||||||
T9400-250G/280P | 330 | 1595 | 1330 | 200 | 545 | 280 | 475 | 14 | 220 | 185 | 1275 | 13 | |
T9400-280G/315P | 325 | 1495 | 1230 | 200 | 545 | 275 | 470 | 14 | 225 | 185 | 1175 | 14 | |
T9400-315G/350P | |||||||||||||
T9400-350G/400P | 335 | 1720 | 1455 | 200 | 545 | 285 | 470 | 14 | 240 | 200 | 1380 | 14 | |
T9400-400G/450P | |||||||||||||
T9400-450G/500P |