Lmf5000-25bxx 5000W 24V 35V 48V Output AC /DC Switch Power Supply

Product Details
Customization: Available
Output Type: Single
Warranty: 1 Year
Manufacturer/Factory

360° Virtual Tour

Diamond Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Quality Assurance
The supplier provides quality assurance
Raw-Materials Traceability
The supplier has traceability identification of raw materials
to see all verified strength labels (23)
  • Lmf5000-25bxx 5000W 24V 35V 48V Output AC /DC Switch Power Supply
  • Lmf5000-25bxx 5000W 24V 35V 48V Output AC /DC Switch Power Supply
  • Lmf5000-25bxx 5000W 24V 35V 48V Output AC /DC Switch Power Supply
  • Lmf5000-25bxx 5000W 24V 35V 48V Output AC /DC Switch Power Supply
  • Lmf5000-25bxx 5000W 24V 35V 48V Output AC /DC Switch Power Supply
  • Lmf5000-25bxx 5000W 24V 35V 48V Output AC /DC Switch Power Supply
Find Similar Products
  • Overview
  • Key features
  • Detailed Photos
Overview

Basic Info.

Model NO.
LMF5000-25Bxx Series
Input Voltage
380V
Connection Mode
Parallel Switching Power Supply
Starting Mode
Self-excited Switching Power Supply
Voltage Regulating Mode
Width Modulation Type
Power Supplying System
Level 1 Power Distribution Equipment
Energy Transmission
One-way Transmission
Modulation System
PWM
Certification
RoHS
Brand
Mornsun
Transport Package
Carton
Specification
5000W
Trademark
Mornsun
Origin
China

Product Description

Key features
 
  1. Input voltage range: 3W+PE196-305VAC or 3W+N+PE Y 340-530VAC or DC input 277-430VDC
  2. Compatible with multiple input modes: 3-phase 4-wire, 3-phase 3-wire, single-phase and DC
  3. PF value up to 0.98
  4. Operating ambient temperature range: -40ºC to +70ºC
  5. Low standby power consumption, high efficiency, low ripple & noise
  6. 20%-120% Ultra-wide range of voltage and current adjustment
  7. Parallel current sharing up to 20000W (3+1)
  8. 485 communication
  9. Double-sided conformal coating
  10. High I/O isolation test voltage up to 4000VAC
  11. Output short circuit, over-current, over-voltage, over-temperature protection
  12. Operating altitude up to 5000m
  13. OVC 
  14. 5 years warranty
  15. Safety according to IEC/EN/UL/BS EN62368
 
LMF5000-25BxxisoneofMornsun'senclosedAC-DCswitchingpowersupply.ItfeaturesuniversalACinputandatthesametimeaccepts DCinputvoltage,coseffective,lownoloadpowerconsumption,highefficiency,highreliabilityanddoubleorreinforcedinsulation.These convertersofferexcellentEMCperformanceandmeetIEC/EN61000-4,CISPR32/EN55032,IEC/EN/UL/BSEN62368standardsandtheyare widelyusedinareasofindustrial,LED,streetlightcontrol,electricity,security,telecommunications,smarthomeetc.
Detailed Photos

 

Lmf5000-25bxx 5000W 24V 35V 48V Output AC /DC Switch Power Supply
 
Selection Guide

Certification

Part No.
Cooling Method Output
Power (W)*
Nominal Output
Voltage and Current (Vo/Io)
Adjustable Range
of Output Voltage ADJ(V)
Efficiency at 230VAC (%)
Typ.
Maximum Capacitive
Load at normal temperature (µF)

--
LMF5000-25B24 Air cooling 4800 24V/200A 23.5-28.8 90 100000
LMF5000-25B36 Air cooling 4968 36V/138A 35-43.2 90.5 44000
LMF5000-25B48 Air cooling 5040 48V/105A 47-57.6 91 25000
Note: *Under any conditions, the total power of the product should not exceed the rated power. When the output voltage is increased, the total output power cannot exceed the rated output power; when the output voltage is decreased, the output current cannot exceed the rated output current.
 
Input Specifications
Item Operating Conditions Min. Typ. Max. Unit



Input Voltage Range
Rated input (Certified voltage) 3W+N+PE, Y Or 3W+PE, Phase voltage 220 -- 277


VAC

AC input

3W+N+PE, Y
Phase voltage 196 -- 305
Line voltage 340 -- 530
3W+PE, 196 -- 305
Single-phase input * 196 -- 305
DC input * 277 -- 430 VDC

Input Voltage Frequency
Rated input (Certified voltage) 47 -- 63
Hz
AC input 47 -- 63

Input Current
Rated input (Certified voltage) -- -- 8

A
230VAC-3W+PE -- -- 15
400VAC-3W+N+PE Y -- -- 9
Inrush Current 230VAC-3W+PE Cold start -- 45 75
                 
  400VAC-3W+N+PE Y   -- 30 50  

Inrush Current Integral (I²t)
230VAC-3W+PE -- 121.5 337.5
A²s
400VAC-3W+N+PE Y -- 54 150
Power Factor 230VAC (Y 400VAC) 0.95 0.98 -- --
Start-up Delay Time 230VAC (Y 400VAC), rated load -- 2200 -- ms
Input Fuse Built-in fuse -- 16 -- A

Input Under-voltage Protection
Under-voltage protection start (Input voltage drops from high to low) 170 -- --
VAC
Under-voltage protection release (Input voltage rises from low to high) -- -- 196
Hot Plug   Unavailable
Note: 1. *Some performance of the product may not be satisfied in single-phase input and DC input, such as output ripple&noise, hold time, etc;
2. *Without special instructions, all performance of the product are measured at 230V, room temperature 25ºC and rated load.
Output Specifications*
Item Operating Conditions Min. Typ. Max. Unit
Output Voltage Accuracy Full load range (normal temperature) -- ±1 --

%
Full load range (High and Low temperature) -- ±3 --
Line Regulation Rated load -- ±0.5 --
Load Regulation 0% - 100% load -- ±0.5 --
Minimum Load   0 -- --
Stand-by Power Consumption   -- 20 -- W


Ripple & Noise*

20MHz bandwidth (peak-peak value)

24V
230VAC-3W+PE -- -- 150

mV
400VAC-3W+N+PE Y -- -- 150

36/48V
230VAC-3W+PE -- -- 200
400VAC-3W+N+PE Y -- -- 200
Temperature Coefficient   -- ±0.03 -- %/ºC
Hold-up Time 230VAC, 75% load 20 -- -- ms
230VAC, rated load 14 -- --
Short Circuit Protection Restart and restore after the short circuit disappear Turn off the output after 5s (typ.) of constant current operation, and restore after restart





Over-current Protection





230VAC, rated load


Normal temperature
110% - 150% Io, two protection modes are available for self-recovery:
  1. Constant current
  2. The output voltage will be turned off after constant current lasting for 5s and will recover
after restarting.


Low temperature, high temperature
110%Io, two protection modes are available for self-recovery:
  1. Constant current
  2. The output voltage will be turned off after constant current lasting for 5s and will recover
after restarting.


Over-voltage Protection
24V 35V (Output voltage off, restart after recovery or clamp)
36V 51V (Output voltage off, restart after recovery or clamp)
48V 68V (Output voltage off, restart after recovery or clamp)

Over-temperature Protection

230VAC,
100% full load
Over-temperature protection start -- -- 95

ºC
Over-temperature protection release 50 -- --
Auxiliary power 12V 12V/0.1A (Used as a signal power supply only)
Note: 1.*Without special instructions, all performance of the product are measured at 230V, room temperature 25ºC and rated load.
2. *The "parallel cable" is used for ripple and noise test, output parallel 47uF electrolytic capacitor and 0.1uF ceramic capacitor, please refer to Enclosed Switching Power Supply Application Notes for specific information.
                 
  
General Specifications
Item Operating Conditions Min. Typ. Max. Unit

Isolation Test*
Input - GND Electric strength test for 1min., leakage current <15mA 2000 -- --
VAC
Input - output Electric strength test for 1min., leakage current <20mA 4000 -- --
Output - GND Electric strength test for 1min., leakage current <15mA 500 -- --

Insulation Resistance
Input - GND Ambient temperature: 25 ± 5ºC
Relative humidity: < 95%RH, no condensation Test voltage: 500VDC
100 -- --
MΩ
Input - output 100 -- --
Output - GND 100 -- --
Operating Temperature   -40 -- +70
ºC
Storage Temperature   -40 -- +85
Operating Humidity
Non-condensing
10 -- 95
%RH
Storage Humidity 20 -- 90

Switching Frequency
PFC -- 65 --
KHz
DC-DC 62 -- 110
Auxiliary source -- 65 --

Power Derating
Operating temperature derating -40ºC to -30ºC 6 -- --
%/ºC
+50ºC to +70ºC 2.5 -- --
Leakage Current 277VAC, 60Hz Touch current <3.5mA
Safety Standards   Design refer to IEC/EN/UL/BS EN62368-1
Safety Class   CLASS I
MTBF MIL-HDBK-217F@25ºC 658,3979 h
Warranty Ambient temperature: <40ºC 5 years
Note: *The discharge tube screw on the side of the case needs to be removed when testing the voltage resistance, and the screw needs to be installed back in place after the test is completed.
Functional Specifications
Item Operating Conditions Min. Typ. Max. Unit

PS_ON Input Signal
Power on PS_ON high 5 -- 18
V
Power off PS_ON low 0 -- 0.8

Accuracy Of Current sharing*
3+1 When multiple machines are connected in parallel, the sub-module shunt more than 50% of the
rated load of every machine
-- ±5 --
%

Remote Compensation
The total compensated voltage value when VS+ and VS- (Pin 7 and Pin 5 of CON2 or CON3) are shorted to both ends of the output load ((VS+ to +Vo, VS- to
-Vo), respectively

--

0.3

--

V

LED Signal
Main output status indication Normal output Green on
Abnormal output, protected Red on
Power off (AC without Input) Light off

External Output Voltage Adjustment*
The output voltage can be adjusted by the external DC power supply. The DC power supply voltage ranges from 1 to 6VDC, corresponding to the output voltage range of
20%-120%Io
24V 4.8 -- 28.8

V
36V 7.2 -- 43.2
48V 9.6 -- 57.6

External Output Current Adjustment*
The output current can be adjusted by the external DC power supply. The DC power supply voltage ranges from 1 to 6VDC, corresponding to the output voltage range of
20%-120%Io
24V 40 -- 240

A
36V 27.6 -- 165.6
48V 21 -- 126

Select The Over-current Protection Mode*

Different over-current protection modes can be selected by adjusting the DIP Switch 1 of the product
By default, the output is turned off after 5s of over-current and the output is restored after restart
When the DIP Switch 1 is selected ON, the output voltage is not less than 50% Vo, which is
  a long-term constant current. When the output voltage is below 50% Vo, the output will be turned off after 5 seconds and restored after restarting.
AC_FAIL   Input voltage loss alarm signal
FAN_FAIL   Fan fault alarm signal
DC_OK   A normal alarm signal is generated
485 Communication   RS485 A and RS485 B communicate
Note: 1.*The voltage difference between each prototype should not exceed 0.2V during current sharing test.
2.*When the DC power supply is adjusted from high to low voltage, the floating OVP protection may be triggered under light load or no load.
3.*When the output voltage and current are adjusted, the actual output voltage and current will have a precision difference of about 10% from the given value of the external power supply. The output voltage or current can be adjusted to the set value by continuing to adjust the external power supply value. When the constant currernt value is >100%Io, long-term work may start OTP protection.
4.*When selecting the external voltage regulation, external current regulation and over-current protection modes, it is required to wait until the auxiliary power is completely powered off before switching the switch.
 
Environmental Characteristics
Item Operating Conditions Standard
High And Low Temperature Working +70ºC, -40ºC GB2423.1, IEC60068-2-1
Sinusoidal Vibration 10 - 500Hz, 2g, three directions of X, Y, Z axis GB2423.10, IEC60068-2-6
Alternating Hot And Humid +25ºC, 95%RH ±60ºC, 95%RH GB2423.4, IEC60068-2-30
Low Temperature Storage -40ºC GB2423.1, IEC60068-2-1
High Temperature Storage +85ºC GB2423.2, IEC60068-2-2
High Temperature Aging +50ºC GB2423.2, IEC60068-2-2
Normal Temperature Aging +25ºC GB2423.1, IEC60068-2-1
Temperature Shock -40ºC to +70ºC GB2423.22, IEC60068-2-14
Packaging Drop 1m, one corner, three edges and six sides GB2423.8, IEC68-2-32
 
General Specifications
Case Material Metal (AL5052, SPCC, SGCC)
Dimensions 460.00mm × 211.00mm × 83.50mm
Weight 7300g (Typ.)
Cooling Method Built-in fan, forced air cooling
 
Electromagnetic Compatibility (EMC)*


Emissions
CE (Input port) CISPR32 EN55032 150K - 30MHz CLASS A
RE CISPR32 EN55032 30MHz -1GHz CLASS A
Harmonic current IEC/EN61000-3-2 CLASS A and CLASS D
Voltage flicker EN61000-3-3 perf. Criteria B





Immunity
ESD IEC/EN61000-4-2        Contact ±8KV/Air ±15KV


perf. Criteria A
RS IEC/EN61000-4-3        10V/m
EFT (Input port) IEC/EN61000-4-4        ±4KV
Surge (Input port) IEC/EN61000-4-5        line-line ±2KV/line-PE ±4KV
MS IEC/EN61000-4-8        30A/m
CS IEC/EN61000-4-6        0.15 - 80MHz 10Vr.m.s

Voltage dips

IEC/EN61000-4-11
>95% dip 0.5 periods perf. Criteria B
30% dip 25 periods perf. Criteria B
Voltage interruption IEC/EN61000-4-11         >95% interruptions 250 periods perf. Criteria B
Note: 1. *perf. Criteria:
A: The equipment shall continue to operate as intended without operator intervention;
B: After the test, the equipment shall continue to operate as intended without operator intervention;
C: Loss of function is allowed, provided the function is self-recoverable, or can be restored by the operation of the controls by the user in accordance with the manufacturer's instructions.
2. *An additional 100cm*80cm*2mm iron plate is required for EMI testing.
 
 
Note:
  1. Unless otherwise specified, parameters in this datasheet were measured under the conditions of Ta=25ºC, humidity <75%RH with nominal input voltage and rated output load;
  2. The room temperature derating of 5ºC/1000m is needed for operating altitude greater than 2000m;
  3. All index testing methods in this datasheet are based on our company corporate standards;
  4. In order to improve the efficiency at high input voltage, there will be audible noise generated, but it does not affect product performance and reliability;
  5. We can provide product customization service, please contact our technicians directly for specific information;
  6. Products are related to laws and regulations: see "Features" and "EMC";
  7. The out case needs to be connected to PE of system when the terminal equipment in operating;
  8. The output voltage can be adjusted by the ADJ, clockwise to increase;
  9. Our products shall be classified according to ISO14001 and related environmental laws and regulations, and shall be handled by qualified units;
  10. The power supply is considered a component which will be installed into a terminal equipment. All EMC tests should be confirmed with the final equipment. Please consult our FAE for EMC test operation instructions.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier